BRAND K KOREAN NATIONAL BRAND

Quick Change Ultimate Inline Water Filter
Model no. HQ9 (FDA Listed)


Overview

Easy to install and maintain !
QUICK Change filter system !

No Water Spilage, Easy Filter Replacement PULL & TURN Quick and Soft Change Water Filter System No Need Electric Clean & Fresh water Space Saving Design.

Big Housing ! Big Capacity !
Available to Combine !
Filter system on Customer demand

Excellent water quality improvement!
Available to Apply HQ9 anywhere, where purified water is needed !

Filter System

ECO MAC 3 IN 1 Filtration System!

The feature of the ECO MAC
Manufacturing Method : Melt-blown(Polypropylene) & Spraying Activated Carbon
Feature of manufacture : It is blocking the polypropylene and activated carbon in one process by using Melt-blown type.
Increasing produce capability : Keep a competitive price by continuous mass- production.
Adsorbability : Excellent adsorbability against injurant materials by using elementary particles of activated carbon.
Excellent flow rate : General sediment levels of flow rate.
Not using a binding materials : Utilize 100% of Activated carbon features by virgin Binder.
Prevention of secondary pollution : To prevent the leak of carbon by core sediment.

300GPD RO MEMBRANE FILTER

The feature of the RO Membrane
Reverse osmosis water filtration systems work by using high pressure to force water through a semipermeable reverse osmosis membrane element. RO membranes are made of a thick polyamide film that contains tiny pores through which water can flow.

WACO Corp. RO membrane filtration process that serves as a barrier to separate substances larger then 0.0001um, such as organics, microorganism, virus, metal ion, cancer-organic substance and other soluble salt in water.

Utilizing advanced membrane technology, WACO Corp. 300 GPD Element offers exceptional balance of flow and premium rejection, ideal for low feed pressure residential applications.

WACO Corp. Reverse osmosis systems have plenty of advantages. They are friendly to the environment, as they do not produce or use any harmful chemicals during the process. These systems also require a minimal amount of power.

Reverse osmosis systems work well in home filtration systems because they are typically small in size. Taste of the purified water is another distinct advantage.
Reverse osmosis filtering dissolved minerals and other contaminants that cause water to smell unpleasant, taste poorly and take on unusual colors.
Filtering of dissolved minerals, metals and other particles benefits plumbing systems. There is nothing in the water to corrode pipes or collect as sediment.

ULTRA FILTRATION UF MEMBRANE FILTER

The feature of the UF Membrane
UF(Ultrafiltration) is one membrane filtration process that serves as a barrier to separate harmful bacteria, viruses, and other contaminants from clean water.
An ultrafiltration water system forces water through a 0.03~0.05 micron membrane. Suspended particles that are too large to pass through the membrane stick to the outer membrane surface.
Only fresh water and dissolved minerals pass through by WACO UF Membrane.

Flow rate of WACO UF membrane is defined as the amount of permeate produced per unit. Our UF filter shows excellent water permeability.
The flow rate varies between 50 and 200 GPD at operating pressure of about 50psi in contrast, Reverse osmosis membranes only produce between 10 to 30GPD at 200 to 400psig.
Quality properties of resistance to acid and alkali, high flow-rate, non-toxicity, no-taste and stable performance.

Specification

Optional Filter System!
Available to combine filter system on customer demand.

HQ9 ? ECO MAC

Melt-Blown(Polypropylene) & Spraying Activated Carbon

Capacity 34000L
  • Combining the polypropylene and activated carbon in one cartridge by using Melt-Blown type process.
  • Excellent Absorbability against harmful substances by using activated carbon.
  • Excellent flow rate : General sediment levels of flow rate.
  • Utilize 100% of Activated carbon features.
Operating Temperature 2-38 ℃
Operating Pressure Under 8kgf/㎠
Flushing 15 mins

HQ9 ? UF MEMBRANE

ULTRAFILTRATION.

Capacity 40000L
  • UF(Ultrafiltration) membrane filtration process that serves as a barrier to separate harmful bacteria, viruses, and other contaminants except minerals.
  • Low operating pressure required.
Operating Temperature 2-38 ℃
Operating Pressure 0.5~4.0kgf/㎠
ph Range 1~14

HQ9 ? RO MEMBRANE 300GPD

REVERSE OSMOSIS WATER FILTRATION SYSTEM

Capacity 300GPD
  • RO membrane filtration process that serves as a barrier to separate substances larger then 0.0001um, such as organics, microorganism, virus, metal ion, cancer-organic substance and other soluble salt in water.
Maximum Operating Temperature 113℉(45℃)
Maximum Operating Pressure 300psi(21bar)
Chlorine Tolerance under 0.1ppm

HQ9 ? ECO PCB

POST CARBON BLOCK

Capacity 20000L
  • PCB Filter makes clean water without color and bad taste by method of filtering that uses a surface of formed carbon block to remove impurities from a fluid using adsorption.
Operating Temperature 2-38 ℃
Operating Pressure Under 8kgf/㎠
Flushing 0~10 mins

HQ9 ? D.I.

DE IONIZATION.

Capacity 6000L
  • Deionization process removes ions from water via ion exchange. Positively charged ions and negatively charged ions (anions) are exchanged for hydrogen (H+) and hydroxyl (OH-) ions, respectively, due to the resin’s greater affinity for other ions.
Operating Temperature 2-38 ℃
Operating Pressure Under 8kgf/㎠
Flushing 0~10 mins

HQ9 ? D.A.

DE ARESENIC

Capacity 10000L
  • The dominant basis of arsenic poisoning is from ground water that naturally Contains high concentrations of arsenic. When the poisoning becomes, symptoms may include diarrhea, vomiting, blood in the urine, cramping muscles, hair loss, stomach pain, and more convulsions. De-Arsenic filter is very effective to remove harmful arsenic in water by strong affinity for absorbing arsenic and other heavy metals.
Operating Temperature 2-38 ℃
Operating Pressure Under 8kgf/㎠
Flushing 0~10 mins

HQ9 ? KDF

Kinetic Degradation Fluxion

Capacity 20000L
  • KDF process media will reduce or remove chlorine, iron, hydrogen sulfide, lead, mercury, magnesium, and chromium, and may inhibit the growth of bacteria, algae, and fungi. More than 98% of chlorine is removed by KDF in home water treatment systems .
Operating Temperature 2-38 ℃
Operating Pressure Under 8kgf/㎠
Flushing 0~10 mins