Features
1. Spun with highly integrated techniques, it shows excellent water
permeability.
2. Using polysulfone as a membrane forming material, it has excellent
chemical and
heat resistance.
3. Filters out all harmful microorganisms and bacteria except minerals.
Specification
of UF Membrane Filter
|
UF
MEMBRANE FILTER |
Flow Rate |
0.5 GPM(1.9L) |
Working Pressure |
7~60 psi (0.5~4.2kgf/cm2) |
Temperature
|
33~100 ¢ªF (4~38 ¡É) |
Capacity
|
3,000 Gal (11,400L) |
PH Range
|
5~10 Hardness below 300ppm |
Service Life
|
12 months |
Evaporated remains
|
Below 500 ppm |
Specification
of UF Hollow Fiber Element Material
Parameter |
specifications |
conditions |
Material |
Polysulfone |
|
Outer Diameter |
450¡¾20¥ìm |
|
Inner Diameter |
270¡¾15¥ìm |
|
particle Size Cut Off |
< 0.03¥ìm |
20¡É, 1kgf/§² |
Pure Water Flux |
50 l/min¡¤§³ |
20¡É, 1kgf/§², initial rate |
Operation Pressure |
0.5-4.0 kgf/§² |
20-30¡É |
pH Range |
1-14 |
|
|
|
|
|
|
|
Pressure
Resistance
1. Applied pressure: 0.5~4 kgf/cm©÷
2. Resident time at each pressure: 5 minutes
3. Maximum operating pressure: 4 kgf/cm©÷ |
|
|
Specification
of UF Hollow Fiber Element Material
- Particle Size Cut Off Character
1. Standard particles: Polystyrene latex bead(Sigma, Mean dia.:
0.03, 0.05 ¥ìm)
2. Pressure: 1 kgf/cm©÷
3. Analysis: UV Spectrometer(¥ë=320 nm)
4. Influent: 100 ppm aqueous suspension
5. Effluent: 7.5 ppm for 0.03 ¥ìm (92.5 % rejected)
1.5 ppm for 0.05 ¥ìm (98.5 % rejected)
- Bacteria Reduction
1. Bacteria: E. Coli
2. Influent: 725 CFU/ml
3. Effluent: Negative(0 CFU/ml, 100% Reduced)
* Certified by KOTRIC(Korea Testing & Research Institute for
Chemical Industry)